Most portable fire pumps used in wildland firefighting are designed around pressure: reaching the fire through long hose lays and uphill. But many operations are limited by a different problem: getting enough water, fast enough, to where it is needed. Filling a truck tank from a reservoir, supplying a portable tank or feeding a relay line are jobs where litres per minute count more than bar.
The vft Black Hawk BH2-18-HF and BH2-23-HF are Vallfirest's answer to that problem: the high-flow (HF) models of the Black Hawk portable pump line, with up to 1,130 L/min (298 US gpm) and up to 13.5 bar (196 PSI).
Key facts
- Maximum flow: 1,130 L/min (298 US gpm) in both versions: more than twice the flow of the standard two-stage Black Hawk BH2 pumps.
- Maximum pressure: 13 bar / 188.5 PSI (BH2-18-HF) and 13.5 bar / 196 PSI (BH2-23-HF).
- Engine: Briggs & Stratton Vanguard V-twin, air-cooled, 18 HP or 23 HP. EU Stage V, EPA and CARB certified.
- Pump: VFT_2SP-HF two-stage High Flow centrifugal pump, driven through a VFT speed increaser.
- Weight and size: 68 kg / 69 kg dry. 81 × 50 × 49 cm (31.8 × 19.6 × 19.2 in).
- Main uses: tank filling, water transfer and supply, long hose lays, tandem and parallel pumping, initial attack.
In this article
- Pressure vs flow: the basics
- Where the BH2-18-HF and BH2-23-HF fit in the Vallfirest fire pump range
- Key benefits
- How it works: the engineering inside
- BH2-18-HF vs BH2-23-HF
- In the field: applications and set-up
- Frequently asked questions
1. Pressure vs flow: the basics
Every centrifugal fire pump works on a performance curve: the more pressure you ask of it, the less flow it can deliver, and vice versa. At maximum pressure, flow is close to zero; at maximum flow, pressure is low. No pump delivers its maximum pressure and its maximum flow at the same time.
Three factors shape that curve:
- Number of stages. Each stage (impeller) adds pressure to the water coming from the previous one. More stages mean more pressure: the right choice for long distances and steep terrain.
- Hydraulic design. Wider impellers and passages move more water per revolution. This is what a High Flow pump does: it shifts the curve towards volume.
- Engine power. The engine sets the limit of the whole system. More horsepower lets the pump sustain more flow as pressure rises.
Choosing a fire pump is therefore choosing where on that curve the operation needs to work: pressure to reach, or volume to supply.
2. Where the BH2-18-HF and BH2-23-HF fit in the Vallfirest fire pump range
Until now, the Vallfirest portable pump range has been built around pressure, from ultralight single-stage units to four-stage pumps reaching almost 29 bar. The HF models open a new category: maximum volume.
| Pump type | Models | Max. pressure | Max. flow | Dry weight | Designed for |
|---|---|---|---|---|---|
| 1 stage | BH1-4H, BH1-2FP | 6.9–7.5 bar (100–109 PSI) |
260–320 L/min (69–85 gpm) |
8.6–9.5 kg | Ultralight units carried to the water source |
| 2 stages | BP2 (lightweight) BH2-10, BH2-13, BH2-18, BH2-21, BH2-23 |
10–15.5 bar (145–225 PSI) |
360–523 L/min (95–138 gpm) |
20 kg (BP2) 49–80 kg (BH2) |
Balance between pressure and flow |
| 3 stages | BH3-10, BH3-13 | 16–23.9 bar (232–347 PSI) |
270–345 L/min (71–91 gpm) |
49.5–59.5 kg | High pressure, long hose lays |
| 4 stages | BP4 (lightweight) BH4-13, BH4-18, BH4-21, BH4-23 |
25.8–28.8 bar (374–418 PSI) |
333–397 L/min (88–105 gpm) |
22 kg (BP4) 60.5–82 kg (BH4) |
Maximum pressure, long distances and steep terrain |
| 2 stages High Flow (new) | BH2-18-HF, BH2-23-HF | 13–13.5 bar (188.5–196 PSI) |
1,130 L/min (298 gpm) |
68–69 kg | Maximum volume: tank filling, transfer and supply |
Ranges according to each model's datasheet. Maximum pressure and maximum flow are not delivered at the same time.
The table shows the trade-off clearly. Compared with the standard two-stage BH2 pumps, the HF models give up around 2 bar of maximum pressure, but deliver more than twice the maximum flow in a unit of similar weight.
3. Key benefits
More than double the flow
Up to 1,130 L/min (298 US gpm), compared with around 520 L/min for a conventional two-stage pump. In practice, flow turns directly into time. Filling a 3,000 L truck tank at maximum flow takes about 2 min 40 s with the BH2-18-HF or the BH2-23-HF, compared with about 5 min 45 s at 520 L/min. That saving is repeated every time a vehicle returns to refill.
Theoretical times at maximum flow, excluding set-up and priming. Real times depend on suction lift, hose diameter and length, elevation and discharge pressure.
Built for water transfer and initial attack
The BH2-18-HF and BH2-23-HF push big volumes high enough to fill truck tanks and portable water tanks, while keeping the pressure needed for initial attack, long hose lays and relay operations. They cover the flow rate the Black Hawk line was missing.
One platform, two power options
18 HP (13 bar / 188.5 PSI) or 23 HP (13.5 bar / 196 PSI), with the same dimensions, frame and pump. Crews choose the power their operation needs without changing how the unit is transported, mounted or maintained.
4. How it works: the engineering inside
The BH2-18-HF and BH2-23-HF are built from the same three main components (engine, speed increaser and pump), plus the equipment needed to operate them.
Briggs & Stratton Vanguard V-twin engine
An air-cooled, four-stroke, two-cylinder gasoline engine from Briggs & Stratton's Vanguard commercial range. It includes an oil level sensor and is certified to EU Stage V, EPA and CARB emission standards. It starts with a manual recoil starter; an electric starter is available as an option (battery not included).
VFT speed increaser
The engine runs at 3,600 rpm, but a high-performance centrifugal pump needs a higher impeller speed. The VFT speed increaser raises the pump shaft speed above engine speed, so the pump reaches its full performance curve. It is maintenance-free, built in cast aluminium with high-quality components.
VFT_2SP-HF two-stage High Flow centrifugal pump
Designed specifically for wildland firefighting, it combines two stages for pressure with high-flow hydraulics for volume:
- Body and impellers in anti-corrosive aluminium, with hard anodising above 400 HV for resistance to abrasion from dirty or sandy water.
- Shaft and internal components in stainless steel.
- Mechanical seal designed specifically for Vallfirest pumps.
- Foam-compatible.
- Connections sized for high flow: inlet 3" NPT or 4" Victaulic, outlet 2.5" NPT or 3" Victaulic.
Interchangeable pump: one power unit, several configurations
The pump is fixed with a quick-release clamp, so it can be replaced in a very short time. The same power unit is also compatible with VFT_2SP (2-stage), VFT_3SP (3-stage) and VFT_4SP (4-stage) pumps. A fleet can adapt a unit from volume to pressure, or get it back in service quickly after a pump failure, without replacing the whole machine.
Included equipment and mounting options
A hand priming pump and a pressure gauge are included. The unit is available with a tubular frame for manoeuvrability or with a base for mounting on vehicles and skid units.
5. BH2-18-HF vs BH2-23-HF
Both versions share the same pump, frame, dimensions and maximum flow. The difference is the engine: 18 HP or 23 HP. The extra power does not raise the maximum flow, but it has a clear effect on how much flow the pump sustains as pressure increases.
| Specification | BH2-18-HF | BH2-23-HF |
|---|---|---|
| Engine | B&S Vanguard V-twin 18 HP | B&S Vanguard V-twin 23 HP |
| Displacement | 570 cm³ | 627 cm³ |
| Bore × stroke | 72.2 × 70 mm | 75.5 × 70 mm |
| Maximum pressure | 13 bar (188.5 PSI) | 13.5 bar (196 PSI) |
| Maximum flow | 1,130 L/min (298 gpm) | 1,130 L/min (298 gpm) |
| Flow at 3.5 bar (50.8 PSI) | 980 L/min (259 gpm) | 1,085 L/min (287 gpm) |
| Flow at 7 bar (101.5 PSI) | 560 L/min (148 gpm) | 750 L/min (198 gpm) |
| Flow at 10.5 bar (152.3 PSI) | 240 L/min (63 gpm) | 360 L/min (95 gpm) |
| Dry weight (complete unit) | 68 kg | 69 kg |
| Dimensions (L × W × H) | 81 × 50 × 49 cm (31.8 × 19.6 × 19.2 in), identical | |
Reading the curve data
- At 3.5 bar, typical of tank filling and short transfers, the two versions are close: the 23 HP delivers about 11% more flow.
- At 7 bar, the gap widens to about 34% more flow with the 23 HP.
- At 10.5 bar, the 23 HP delivers 50% more flow.
Which one to choose
- BH2-18-HF: when the main job is moving volume at low to moderate pressure, such as filling truck and portable tanks, transfer from reservoirs and short supply lines on flat or gentle terrain.
- BH2-23-HF: when the pump also has to work against pressure, such as longer hose lays, elevation gain, feeding a relay or supporting initial attack while keeping high flow.
6. In the field: applications and set-up
Applications
- Tank filling: truck tanks and portable water tanks from open water sources.
- Water transfer and supply: moving water from a reservoir, river or pond to where operations need it.
- Direct attack with high flow available at the nozzles.
- Long hose lays.
- Tandem (series) pumping: several pumps along one line, each boosting pressure, to cover long distances.
- Parallel pumping: several pumps feeding the same point to multiply volume.
- Self-protection manoeuvres with sprinklers.
- Assembly in skid units and firefighting vehicles.
Set-up: what a high-flow pump needs
A high-flow pump only delivers its performance if the rest of the system lets water in and out freely.
- Suction: a suction hose and a foot valve are required. The foot valve filters the water and keeps the line full once primed. Keep the pump as close to the water level as possible: the higher the suction lift, the less flow the pump can draw.
- Priming: centrifugal pumps do not self-prime. Use the included hand priming pump to fill the suction line before starting.
- Hose diameter: friction losses rise sharply with flow. To take advantage of 1,130 L/min, use hose and couplings sized for high flow on both suction and discharge.
- Couplings and adapters: choose them according to the hose type and the layout (direct attack, series or parallel). A coupling wrench is needed for thread protectors and adapters.
- Fuel: for long operations, an external 12 L or 25 L fuel tank extends operating time without refuelling.
7. Frequently asked questions
What is a high-flow portable fire pump?
A portable fire pump whose hydraulics are designed to move large volumes of water rather than to reach very high pressures. It is used mainly for tank filling, water transfer and supply lines. The Vallfirest BH2-18-HF and BH2-23-HF deliver up to 1,130 L/min (298 US gpm).
What are the maximum flow and pressure of the Black Hawk BH2-18-HF and BH2-23-HF?
Both versions deliver up to 1,130 L/min (298 US gpm). Maximum pressure is 13 bar (188.5 PSI) for the BH2-18-HF and 13.5 bar (196 PSI) for the BH2-23-HF. Maximum flow and maximum pressure are not reached at the same time.
What is the difference between the BH2-18-HF and the BH2-23-HF?
The engine: 18 HP or 23 HP. Both have the same pump, frame, dimensions and maximum flow. The 23 HP sustains more flow as pressure rises: about 11% more at 3.5 bar, 34% more at 7 bar and 50% more at 10.5 bar.
How do the BH2-18-HF and BH2-23-HF compare with the standard two-stage Black Hawk BH2 pumps?
The standard BH2 pumps reach up to 15.5 bar and around 520 L/min. The HF models give up around 2 bar of maximum pressure in exchange for more than twice the maximum flow, at a similar weight.
How long does it take to fill a 3,000 L tank?
At maximum flow (1,130 L/min), about 2 minutes 40 seconds, excluding set-up and priming. Real times depend on suction lift, hose diameter and length, elevation and discharge pressure.
Can the BH2-18-HF and BH2-23-HF be used for tandem or parallel pumping?
Yes. Both can work in tandem (series), with several pumps along one line to cover long distances, or in parallel, with several pumps feeding the same point to increase volume.
Can the pump be replaced or changed?
Yes. The VFT_2SP-HF pump is fixed with a quick-release clamp and can be replaced in a very short time. The power unit is also compatible with VFT_2SP (2-stage), VFT_3SP (3-stage) and VFT_4SP (4-stage) pumps.
Are the BH2-18-HF and BH2-23-HF compatible with foam?
Yes. The pump is compatible with foam-forming agents.
How are the BH2-18-HF and BH2-23-HF started?
Both have a manual recoil starter. An electric starter is available as an option (battery not included).
Can the BH2-18-HF and BH2-23-HF be mounted on a vehicle?
Yes. Both are available with a tubular frame for portable use or with a base for mounting on vehicles and skid units.
What do I need to operate the BH2-18-HF or BH2-23-HF?
A suction hose and foot valve, discharge hoses and couplings suited to the layout, and a coupling wrench. The hand priming pump and pressure gauge are included. An external 12 L or 25 L fuel tank is recommended for long operations.
What warranty do the BH2-18-HF and BH2-23-HF have?
A 2-year warranty. Spare parts and technical support are available through [email protected].